Cargando…

Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions

This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geote...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Yalong, Wang, Xu, Guo, Chunxiang, Hu, Yuan, He, Fei, Liu, Deren, Jiang, Daijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9737892/
https://www.ncbi.nlm.nih.gov/pubmed/36499982
http://dx.doi.org/10.3390/ma15238470
_version_ 1784847401848143872
author Zhou, Yalong
Wang, Xu
Guo, Chunxiang
Hu, Yuan
He, Fei
Liu, Deren
Jiang, Daijun
author_facet Zhou, Yalong
Wang, Xu
Guo, Chunxiang
Hu, Yuan
He, Fei
Liu, Deren
Jiang, Daijun
author_sort Zhou, Yalong
collection PubMed
description This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geotemperature, a coupled air temperature–L-shaped TPCT–subgrade soil heat transfer model was established using the ANSYS 15.0 software platform, and the rationality of the model was verified through measured data. The heat-transfer characteristics of the L-shaped TPCTs and the long-term thermal stability of the subgrade were studied under different inclination angles of the evaporator (α = 15°, 30°, 50°, 70°, and 90°). Then, the cooling effectiveness of a composite subgrade with TPCTs and an XPS insulation board was numerically calculated. The results show that the heat flux of the L-shaped TPCT was the greatest when α = 50°, and the heat flux reached the maximum value of 165.7 W·m(−2) in January. The L-shaped TPCT had a relatively good cooling effect on the subgrade as a whole when α = 50° and 70°, but the thawing depth at the center of the subgrade with L-shaped TPCTs reached 9.0 m below the ground surface in the 30th year. The composite subgrade with L-shaped TPCTs/vertical TPCT/XPS insulation board is an effective method to protect the permafrost foundation and improve the long-term thermal stability of the wide subgrade. The maximum heat flux of evaporation section of the L-shaped TPCT is 18.8% higher than that of the vertical TPCT during the working period of the TPCTs of the composite subgrade.
format Online
Article
Text
id pubmed-9737892
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97378922022-12-11 Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions Zhou, Yalong Wang, Xu Guo, Chunxiang Hu, Yuan He, Fei Liu, Deren Jiang, Daijun Materials (Basel) Article This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geotemperature, a coupled air temperature–L-shaped TPCT–subgrade soil heat transfer model was established using the ANSYS 15.0 software platform, and the rationality of the model was verified through measured data. The heat-transfer characteristics of the L-shaped TPCTs and the long-term thermal stability of the subgrade were studied under different inclination angles of the evaporator (α = 15°, 30°, 50°, 70°, and 90°). Then, the cooling effectiveness of a composite subgrade with TPCTs and an XPS insulation board was numerically calculated. The results show that the heat flux of the L-shaped TPCT was the greatest when α = 50°, and the heat flux reached the maximum value of 165.7 W·m(−2) in January. The L-shaped TPCT had a relatively good cooling effect on the subgrade as a whole when α = 50° and 70°, but the thawing depth at the center of the subgrade with L-shaped TPCTs reached 9.0 m below the ground surface in the 30th year. The composite subgrade with L-shaped TPCTs/vertical TPCT/XPS insulation board is an effective method to protect the permafrost foundation and improve the long-term thermal stability of the wide subgrade. The maximum heat flux of evaporation section of the L-shaped TPCT is 18.8% higher than that of the vertical TPCT during the working period of the TPCTs of the composite subgrade. MDPI 2022-11-28 /pmc/articles/PMC9737892/ /pubmed/36499982 http://dx.doi.org/10.3390/ma15238470 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhou, Yalong
Wang, Xu
Guo, Chunxiang
Hu, Yuan
He, Fei
Liu, Deren
Jiang, Daijun
Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
title Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
title_full Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
title_fullStr Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
title_full_unstemmed Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
title_short Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
title_sort cooling subgrade effectiveness by l-shaped two-phase closed thermosyphons with different inclination angles and xps insulation boards in permafrost regions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9737892/
https://www.ncbi.nlm.nih.gov/pubmed/36499982
http://dx.doi.org/10.3390/ma15238470
work_keys_str_mv AT zhouyalong coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions
AT wangxu coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions
AT guochunxiang coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions
AT huyuan coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions
AT hefei coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions
AT liuderen coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions
AT jiangdaijun coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions