Cargando…
Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geote...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9737892/ https://www.ncbi.nlm.nih.gov/pubmed/36499982 http://dx.doi.org/10.3390/ma15238470 |
_version_ | 1784847401848143872 |
---|---|
author | Zhou, Yalong Wang, Xu Guo, Chunxiang Hu, Yuan He, Fei Liu, Deren Jiang, Daijun |
author_facet | Zhou, Yalong Wang, Xu Guo, Chunxiang Hu, Yuan He, Fei Liu, Deren Jiang, Daijun |
author_sort | Zhou, Yalong |
collection | PubMed |
description | This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geotemperature, a coupled air temperature–L-shaped TPCT–subgrade soil heat transfer model was established using the ANSYS 15.0 software platform, and the rationality of the model was verified through measured data. The heat-transfer characteristics of the L-shaped TPCTs and the long-term thermal stability of the subgrade were studied under different inclination angles of the evaporator (α = 15°, 30°, 50°, 70°, and 90°). Then, the cooling effectiveness of a composite subgrade with TPCTs and an XPS insulation board was numerically calculated. The results show that the heat flux of the L-shaped TPCT was the greatest when α = 50°, and the heat flux reached the maximum value of 165.7 W·m(−2) in January. The L-shaped TPCT had a relatively good cooling effect on the subgrade as a whole when α = 50° and 70°, but the thawing depth at the center of the subgrade with L-shaped TPCTs reached 9.0 m below the ground surface in the 30th year. The composite subgrade with L-shaped TPCTs/vertical TPCT/XPS insulation board is an effective method to protect the permafrost foundation and improve the long-term thermal stability of the wide subgrade. The maximum heat flux of evaporation section of the L-shaped TPCT is 18.8% higher than that of the vertical TPCT during the working period of the TPCTs of the composite subgrade. |
format | Online Article Text |
id | pubmed-9737892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97378922022-12-11 Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions Zhou, Yalong Wang, Xu Guo, Chunxiang Hu, Yuan He, Fei Liu, Deren Jiang, Daijun Materials (Basel) Article This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geotemperature, a coupled air temperature–L-shaped TPCT–subgrade soil heat transfer model was established using the ANSYS 15.0 software platform, and the rationality of the model was verified through measured data. The heat-transfer characteristics of the L-shaped TPCTs and the long-term thermal stability of the subgrade were studied under different inclination angles of the evaporator (α = 15°, 30°, 50°, 70°, and 90°). Then, the cooling effectiveness of a composite subgrade with TPCTs and an XPS insulation board was numerically calculated. The results show that the heat flux of the L-shaped TPCT was the greatest when α = 50°, and the heat flux reached the maximum value of 165.7 W·m(−2) in January. The L-shaped TPCT had a relatively good cooling effect on the subgrade as a whole when α = 50° and 70°, but the thawing depth at the center of the subgrade with L-shaped TPCTs reached 9.0 m below the ground surface in the 30th year. The composite subgrade with L-shaped TPCTs/vertical TPCT/XPS insulation board is an effective method to protect the permafrost foundation and improve the long-term thermal stability of the wide subgrade. The maximum heat flux of evaporation section of the L-shaped TPCT is 18.8% higher than that of the vertical TPCT during the working period of the TPCTs of the composite subgrade. MDPI 2022-11-28 /pmc/articles/PMC9737892/ /pubmed/36499982 http://dx.doi.org/10.3390/ma15238470 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhou, Yalong Wang, Xu Guo, Chunxiang Hu, Yuan He, Fei Liu, Deren Jiang, Daijun Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions |
title | Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions |
title_full | Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions |
title_fullStr | Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions |
title_full_unstemmed | Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions |
title_short | Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions |
title_sort | cooling subgrade effectiveness by l-shaped two-phase closed thermosyphons with different inclination angles and xps insulation boards in permafrost regions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9737892/ https://www.ncbi.nlm.nih.gov/pubmed/36499982 http://dx.doi.org/10.3390/ma15238470 |
work_keys_str_mv | AT zhouyalong coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions AT wangxu coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions AT guochunxiang coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions AT huyuan coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions AT hefei coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions AT liuderen coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions AT jiangdaijun coolingsubgradeeffectivenessbylshapedtwophaseclosedthermosyphonswithdifferentinclinationanglesandxpsinsulationboardsinpermafrostregions |