Cargando…

Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure

I Microhotplates are critical devices in various MEMS sensors that could provide appropriate operating temperatures. In this paper, a novel design of poly-Si membrane microhotplates with a heat compensation structure was reported. The main objective of this work was to design and fabricate the poly-...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Xiaorui, Liu, Jiahui, Han, Guowei, Si, Chaowei, Zhao, Yongmei, Hou, Zhongxuan, Zhang, Yongkang, Ning, Jin, Yang, Fuhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9782555/
https://www.ncbi.nlm.nih.gov/pubmed/36557388
http://dx.doi.org/10.3390/mi13122090
_version_ 1784857371385790464
author Lu, Xiaorui
Liu, Jiahui
Han, Guowei
Si, Chaowei
Zhao, Yongmei
Hou, Zhongxuan
Zhang, Yongkang
Ning, Jin
Yang, Fuhua
author_facet Lu, Xiaorui
Liu, Jiahui
Han, Guowei
Si, Chaowei
Zhao, Yongmei
Hou, Zhongxuan
Zhang, Yongkang
Ning, Jin
Yang, Fuhua
author_sort Lu, Xiaorui
collection PubMed
description I Microhotplates are critical devices in various MEMS sensors that could provide appropriate operating temperatures. In this paper, a novel design of poly-Si membrane microhotplates with a heat compensation structure was reported. The main objective of this work was to design and fabricate the poly-Si microhotplate, and the thermal and electrical performance of the microhotplates were also investigated. The poly-Si resistive heater was deposited by LPCVD, and phosphorous doping was applied by in situ doping process to reduce the resistance of poly-Si. In order to obtain a uniform temperature distribution, a series of S-shaped compensation structures were fabricated at the edge of the resistive heater. LPCVD SiNx layers deposited on both sides of poly-Si were used as both the mechanical supporting layer and the electrical isolation layer. The Pt electrode was fabricated on the top of the microhotplate for temperature detection. The area of the heating membrane was 1 mm × 1 mm. Various parameters of the different size devices were simulated and measured, including temperature distribution, power consumption, thermal expansion and response time. The simulation and electrical–thermal measurement results were reported. For microhotplates with a heat compensation structure, the membrane temperature reached 811.7 °C when the applied voltage was 5.5 V at a heating power of 148.3 mW. A 3.8 V DC voltage was applied to measure the temperature distribution; the maximum temperature was 397.6 °C, and the area where the temperature reached 90% covered about 73.8% when the applied voltage was 3.8 V at a heating power of 70.8 mW. The heating response time was 17 ms while the microhotplate was heated to 400 °C from room temperature, and the cooling response time was 32 ms while the device was recovered to room temperature. This microhotplate has many advantages, such as uniform temperature distribution, low power consumption and fast response, which are suitable for MEMS gas sensors, humidity sensors, gas flow sensors, etc.
format Online
Article
Text
id pubmed-9782555
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97825552022-12-24 Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure Lu, Xiaorui Liu, Jiahui Han, Guowei Si, Chaowei Zhao, Yongmei Hou, Zhongxuan Zhang, Yongkang Ning, Jin Yang, Fuhua Micromachines (Basel) Article I Microhotplates are critical devices in various MEMS sensors that could provide appropriate operating temperatures. In this paper, a novel design of poly-Si membrane microhotplates with a heat compensation structure was reported. The main objective of this work was to design and fabricate the poly-Si microhotplate, and the thermal and electrical performance of the microhotplates were also investigated. The poly-Si resistive heater was deposited by LPCVD, and phosphorous doping was applied by in situ doping process to reduce the resistance of poly-Si. In order to obtain a uniform temperature distribution, a series of S-shaped compensation structures were fabricated at the edge of the resistive heater. LPCVD SiNx layers deposited on both sides of poly-Si were used as both the mechanical supporting layer and the electrical isolation layer. The Pt electrode was fabricated on the top of the microhotplate for temperature detection. The area of the heating membrane was 1 mm × 1 mm. Various parameters of the different size devices were simulated and measured, including temperature distribution, power consumption, thermal expansion and response time. The simulation and electrical–thermal measurement results were reported. For microhotplates with a heat compensation structure, the membrane temperature reached 811.7 °C when the applied voltage was 5.5 V at a heating power of 148.3 mW. A 3.8 V DC voltage was applied to measure the temperature distribution; the maximum temperature was 397.6 °C, and the area where the temperature reached 90% covered about 73.8% when the applied voltage was 3.8 V at a heating power of 70.8 mW. The heating response time was 17 ms while the microhotplate was heated to 400 °C from room temperature, and the cooling response time was 32 ms while the device was recovered to room temperature. This microhotplate has many advantages, such as uniform temperature distribution, low power consumption and fast response, which are suitable for MEMS gas sensors, humidity sensors, gas flow sensors, etc. MDPI 2022-11-27 /pmc/articles/PMC9782555/ /pubmed/36557388 http://dx.doi.org/10.3390/mi13122090 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lu, Xiaorui
Liu, Jiahui
Han, Guowei
Si, Chaowei
Zhao, Yongmei
Hou, Zhongxuan
Zhang, Yongkang
Ning, Jin
Yang, Fuhua
Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure
title Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure
title_full Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure
title_fullStr Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure
title_full_unstemmed Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure
title_short Design and Fabrication of a Novel Poly-Si Microhotplate with Heat Compensation Structure
title_sort design and fabrication of a novel poly-si microhotplate with heat compensation structure
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9782555/
https://www.ncbi.nlm.nih.gov/pubmed/36557388
http://dx.doi.org/10.3390/mi13122090
work_keys_str_mv AT luxiaorui designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT liujiahui designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT hanguowei designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT sichaowei designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT zhaoyongmei designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT houzhongxuan designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT zhangyongkang designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT ningjin designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure
AT yangfuhua designandfabricationofanovelpolysimicrohotplatewithheatcompensationstructure