Cargando…

LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification

The quantitation of serum tocilizumab using liquid chromatography tandem-mass spectrometry (LC-MS/MS) method has not been widely applied in clinical settings because of its time-consuming and costly sample pretreatments. The present study aimed to develop a validated LC-MS/MS method for detecting se...

Descripción completa

Detalles Bibliográficos
Autores principales: Mochizuki, Takashi, Shibata, Kaito, Naito, Takafumi, Shimoyama, Kumiko, Ogawa, Noriyoshi, Maekawa, Masato, Kawakami, Junichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805942/
https://www.ncbi.nlm.nih.gov/pubmed/36605577
http://dx.doi.org/10.1016/j.jpha.2022.08.003
_version_ 1784862428946759680
author Mochizuki, Takashi
Shibata, Kaito
Naito, Takafumi
Shimoyama, Kumiko
Ogawa, Noriyoshi
Maekawa, Masato
Kawakami, Junichi
author_facet Mochizuki, Takashi
Shibata, Kaito
Naito, Takafumi
Shimoyama, Kumiko
Ogawa, Noriyoshi
Maekawa, Masato
Kawakami, Junichi
author_sort Mochizuki, Takashi
collection PubMed
description The quantitation of serum tocilizumab using liquid chromatography tandem-mass spectrometry (LC-MS/MS) method has not been widely applied in clinical settings because of its time-consuming and costly sample pretreatments. The present study aimed to develop a validated LC-MS/MS method for detecting serum tocilizumab by utilizing immobilized trypsin without an immunoglobulin G purification step and evaluate its applicability in the treatment of rheumatoid arthritis (RA) patients administered intravenously or subcutaneously with tocilizumab. The tocilizumab-derived signature peptide was deciphered using a nano-LC system coupled to a hybrid quadrupole-orbitrap mass spectrometer. The serum tocilizumab was rapidly digested by immobilized trypsin for 30 min. The chromatographic peak of the signature peptide and that of the internal standard were separated from the serum digests for a total run time of 15 min. The calibration curve of serum tocilizumab concentration was linear with a range of 2–200 μg/mL. The intra- and inter-day accuracy and relative standard deviation (RSD) were 90.7%–109.4% and <10%, respectively. The serum tocilizumab concentrations in the RA patients receiving intravenous and subcutaneous injections were 5.8–28.9 and 2.4–63.5 μg/mL, respectively. The serum tocilizumab concentrations using the current method positively correlated with those using the enzyme-linked immunosorbent assay, although a systematic error was observed between these methods. In conclusion, a validated LC-MS/MS method with minimal sample pretreatments for monitoring serum tocilizumab concentrations in RA patients was developed.
format Online
Article
Text
id pubmed-9805942
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-98059422023-01-04 LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification Mochizuki, Takashi Shibata, Kaito Naito, Takafumi Shimoyama, Kumiko Ogawa, Noriyoshi Maekawa, Masato Kawakami, Junichi J Pharm Anal Original Article The quantitation of serum tocilizumab using liquid chromatography tandem-mass spectrometry (LC-MS/MS) method has not been widely applied in clinical settings because of its time-consuming and costly sample pretreatments. The present study aimed to develop a validated LC-MS/MS method for detecting serum tocilizumab by utilizing immobilized trypsin without an immunoglobulin G purification step and evaluate its applicability in the treatment of rheumatoid arthritis (RA) patients administered intravenously or subcutaneously with tocilizumab. The tocilizumab-derived signature peptide was deciphered using a nano-LC system coupled to a hybrid quadrupole-orbitrap mass spectrometer. The serum tocilizumab was rapidly digested by immobilized trypsin for 30 min. The chromatographic peak of the signature peptide and that of the internal standard were separated from the serum digests for a total run time of 15 min. The calibration curve of serum tocilizumab concentration was linear with a range of 2–200 μg/mL. The intra- and inter-day accuracy and relative standard deviation (RSD) were 90.7%–109.4% and <10%, respectively. The serum tocilizumab concentrations in the RA patients receiving intravenous and subcutaneous injections were 5.8–28.9 and 2.4–63.5 μg/mL, respectively. The serum tocilizumab concentrations using the current method positively correlated with those using the enzyme-linked immunosorbent assay, although a systematic error was observed between these methods. In conclusion, a validated LC-MS/MS method with minimal sample pretreatments for monitoring serum tocilizumab concentrations in RA patients was developed. Xi'an Jiaotong University 2022-12 2022-09-02 /pmc/articles/PMC9805942/ /pubmed/36605577 http://dx.doi.org/10.1016/j.jpha.2022.08.003 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Mochizuki, Takashi
Shibata, Kaito
Naito, Takafumi
Shimoyama, Kumiko
Ogawa, Noriyoshi
Maekawa, Masato
Kawakami, Junichi
LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
title LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
title_full LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
title_fullStr LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
title_full_unstemmed LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
title_short LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
title_sort lc-ms/ms method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without igg purification
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805942/
https://www.ncbi.nlm.nih.gov/pubmed/36605577
http://dx.doi.org/10.1016/j.jpha.2022.08.003
work_keys_str_mv AT mochizukitakashi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification
AT shibatakaito lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification
AT naitotakafumi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification
AT shimoyamakumiko lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification
AT ogawanoriyoshi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification
AT maekawamasato lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification
AT kawakamijunichi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification