Cargando…
LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification
The quantitation of serum tocilizumab using liquid chromatography tandem-mass spectrometry (LC-MS/MS) method has not been widely applied in clinical settings because of its time-consuming and costly sample pretreatments. The present study aimed to develop a validated LC-MS/MS method for detecting se...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805942/ https://www.ncbi.nlm.nih.gov/pubmed/36605577 http://dx.doi.org/10.1016/j.jpha.2022.08.003 |
_version_ | 1784862428946759680 |
---|---|
author | Mochizuki, Takashi Shibata, Kaito Naito, Takafumi Shimoyama, Kumiko Ogawa, Noriyoshi Maekawa, Masato Kawakami, Junichi |
author_facet | Mochizuki, Takashi Shibata, Kaito Naito, Takafumi Shimoyama, Kumiko Ogawa, Noriyoshi Maekawa, Masato Kawakami, Junichi |
author_sort | Mochizuki, Takashi |
collection | PubMed |
description | The quantitation of serum tocilizumab using liquid chromatography tandem-mass spectrometry (LC-MS/MS) method has not been widely applied in clinical settings because of its time-consuming and costly sample pretreatments. The present study aimed to develop a validated LC-MS/MS method for detecting serum tocilizumab by utilizing immobilized trypsin without an immunoglobulin G purification step and evaluate its applicability in the treatment of rheumatoid arthritis (RA) patients administered intravenously or subcutaneously with tocilizumab. The tocilizumab-derived signature peptide was deciphered using a nano-LC system coupled to a hybrid quadrupole-orbitrap mass spectrometer. The serum tocilizumab was rapidly digested by immobilized trypsin for 30 min. The chromatographic peak of the signature peptide and that of the internal standard were separated from the serum digests for a total run time of 15 min. The calibration curve of serum tocilizumab concentration was linear with a range of 2–200 μg/mL. The intra- and inter-day accuracy and relative standard deviation (RSD) were 90.7%–109.4% and <10%, respectively. The serum tocilizumab concentrations in the RA patients receiving intravenous and subcutaneous injections were 5.8–28.9 and 2.4–63.5 μg/mL, respectively. The serum tocilizumab concentrations using the current method positively correlated with those using the enzyme-linked immunosorbent assay, although a systematic error was observed between these methods. In conclusion, a validated LC-MS/MS method with minimal sample pretreatments for monitoring serum tocilizumab concentrations in RA patients was developed. |
format | Online Article Text |
id | pubmed-9805942 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-98059422023-01-04 LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification Mochizuki, Takashi Shibata, Kaito Naito, Takafumi Shimoyama, Kumiko Ogawa, Noriyoshi Maekawa, Masato Kawakami, Junichi J Pharm Anal Original Article The quantitation of serum tocilizumab using liquid chromatography tandem-mass spectrometry (LC-MS/MS) method has not been widely applied in clinical settings because of its time-consuming and costly sample pretreatments. The present study aimed to develop a validated LC-MS/MS method for detecting serum tocilizumab by utilizing immobilized trypsin without an immunoglobulin G purification step and evaluate its applicability in the treatment of rheumatoid arthritis (RA) patients administered intravenously or subcutaneously with tocilizumab. The tocilizumab-derived signature peptide was deciphered using a nano-LC system coupled to a hybrid quadrupole-orbitrap mass spectrometer. The serum tocilizumab was rapidly digested by immobilized trypsin for 30 min. The chromatographic peak of the signature peptide and that of the internal standard were separated from the serum digests for a total run time of 15 min. The calibration curve of serum tocilizumab concentration was linear with a range of 2–200 μg/mL. The intra- and inter-day accuracy and relative standard deviation (RSD) were 90.7%–109.4% and <10%, respectively. The serum tocilizumab concentrations in the RA patients receiving intravenous and subcutaneous injections were 5.8–28.9 and 2.4–63.5 μg/mL, respectively. The serum tocilizumab concentrations using the current method positively correlated with those using the enzyme-linked immunosorbent assay, although a systematic error was observed between these methods. In conclusion, a validated LC-MS/MS method with minimal sample pretreatments for monitoring serum tocilizumab concentrations in RA patients was developed. Xi'an Jiaotong University 2022-12 2022-09-02 /pmc/articles/PMC9805942/ /pubmed/36605577 http://dx.doi.org/10.1016/j.jpha.2022.08.003 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Mochizuki, Takashi Shibata, Kaito Naito, Takafumi Shimoyama, Kumiko Ogawa, Noriyoshi Maekawa, Masato Kawakami, Junichi LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification |
title | LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification |
title_full | LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification |
title_fullStr | LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification |
title_full_unstemmed | LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification |
title_short | LC-MS/MS method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without IgG purification |
title_sort | lc-ms/ms method for the quantitation of serum tocilizumab in rheumatoid arthritis patients using rapid tryptic digestion without igg purification |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9805942/ https://www.ncbi.nlm.nih.gov/pubmed/36605577 http://dx.doi.org/10.1016/j.jpha.2022.08.003 |
work_keys_str_mv | AT mochizukitakashi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification AT shibatakaito lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification AT naitotakafumi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification AT shimoyamakumiko lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification AT ogawanoriyoshi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification AT maekawamasato lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification AT kawakamijunichi lcmsmsmethodforthequantitationofserumtocilizumabinrheumatoidarthritispatientsusingrapidtrypticdigestionwithoutiggpurification |