Cargando…

Ophthalmic artery flow direction change predicts recurrence of ischemic stroke after carotid stenting: a longitudinal observational study

BACKGROUND AND PURPOSE: The implantation of carotid artery stents prevents recurrent ischemic stroke in patients with carotid stenosis. This study aimed to investigate associations between change of ophthalmic artery flow (COAF) post carotid stenting and recurrent ischemic stroke, as well as the lin...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Hui-Yi, Lian, Ie-Bin, Wang, Shih-Chun, Lin, Ta-Tsung, Ou, Yang-Hao, Liu, Chi-Kuang, Lin, Chih-Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9806874/
https://www.ncbi.nlm.nih.gov/pubmed/36593520
http://dx.doi.org/10.1186/s40001-022-00965-9