Membrane Distillation Crystallizer Applied for Separation of NaCl Solutions Contaminated with Oil

In the present study, the membrane crystallizer was used to separate a saturated NaCl solution contaminated with an oil emulsion. The crystallizer was connected via a mesh separator with a feed tank in which capillary submerged modules were assembled. The effect of scaling and oil sorption on the we...