A comparative study of pulse pressure variation, stroke volume variation and central venous pressure in patients undergoing kidney transplantation

INTRODUCTION: Optimal intraoperative fluid management guided by central venous pressure (CVP), a traditional intravascular volume status indicator, has improved transplanted graft function during kidney transplantation (KT). Pulse pressure variation (PPV) and stroke volume variation (SVV) – dynamic...