A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection
This paper presents an implementation scheme and experimental evaluation of a high-linearity closed-loop capacitive accelerometer based on ring-diode capacitance detection. By deducing the capacitance detection model of the ring-diode considering the influence of the diode, the existing theoretical...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921293/ https://www.ncbi.nlm.nih.gov/pubmed/36772607 http://dx.doi.org/10.3390/s23031568 |
_version_ | 1784887277986512896 |
---|---|
author | Tao, Qi Tang, Bin |
author_facet | Tao, Qi Tang, Bin |
author_sort | Tao, Qi |
collection | PubMed |
description | This paper presents an implementation scheme and experimental evaluation of a high-linearity closed-loop capacitive accelerometer based on ring-diode capacitance detection. By deducing the capacitance detection model of the ring-diode considering the influence of the diode, the existing theoretical model error of the ring-diode is corrected and a closed-loop scheme of reusing the detection electrode and the control electrode of the MEMS die is designed to apply this detection scheme to the parallel-plate accelerometer, which only has three independent electrodes. After analyzing the non-linear problems in the existing closed-loop control schemes, a theoretically absolute linear closed-loop control scheme is proposed, and an integrated closed-loop accelerometer is realized by combining the closed-loop diode detection. The experimental results of the ring-diode detection model are in agreement with the theoretical formula. The non-linearity of the accelerometer within ±1 g after the closed-loop is 130 ppm, compared with 1500 ppm when the open-loop is used. |
format | Online Article Text |
id | pubmed-9921293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99212932023-02-12 A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection Tao, Qi Tang, Bin Sensors (Basel) Article This paper presents an implementation scheme and experimental evaluation of a high-linearity closed-loop capacitive accelerometer based on ring-diode capacitance detection. By deducing the capacitance detection model of the ring-diode considering the influence of the diode, the existing theoretical model error of the ring-diode is corrected and a closed-loop scheme of reusing the detection electrode and the control electrode of the MEMS die is designed to apply this detection scheme to the parallel-plate accelerometer, which only has three independent electrodes. After analyzing the non-linear problems in the existing closed-loop control schemes, a theoretically absolute linear closed-loop control scheme is proposed, and an integrated closed-loop accelerometer is realized by combining the closed-loop diode detection. The experimental results of the ring-diode detection model are in agreement with the theoretical formula. The non-linearity of the accelerometer within ±1 g after the closed-loop is 130 ppm, compared with 1500 ppm when the open-loop is used. MDPI 2023-02-01 /pmc/articles/PMC9921293/ /pubmed/36772607 http://dx.doi.org/10.3390/s23031568 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tao, Qi Tang, Bin A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection |
title | A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection |
title_full | A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection |
title_fullStr | A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection |
title_full_unstemmed | A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection |
title_short | A High-Linearity Closed-Loop Capacitive Micro-Accelerometer Based on Ring-Diode Capacitance Detection |
title_sort | high-linearity closed-loop capacitive micro-accelerometer based on ring-diode capacitance detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921293/ https://www.ncbi.nlm.nih.gov/pubmed/36772607 http://dx.doi.org/10.3390/s23031568 |
work_keys_str_mv | AT taoqi ahighlinearityclosedloopcapacitivemicroaccelerometerbasedonringdiodecapacitancedetection AT tangbin ahighlinearityclosedloopcapacitivemicroaccelerometerbasedonringdiodecapacitancedetection AT taoqi highlinearityclosedloopcapacitivemicroaccelerometerbasedonringdiodecapacitancedetection AT tangbin highlinearityclosedloopcapacitivemicroaccelerometerbasedonringdiodecapacitancedetection |