Cargando…
Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase
On average, arterial oxygen saturation measured by pulse oximetry (SpO(2)) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO(2)), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO(2) on 17 cyanotic newborns were performed by me...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921559/ https://www.ncbi.nlm.nih.gov/pubmed/36772474 http://dx.doi.org/10.3390/s23031434 |
_version_ | 1784887341090865152 |
---|---|
author | Elron, Eyal Bromiker, Ruben Gleisner, Ori Yosef-Hai, Ohad Goldberg, Ori Nitzan, Itamar Nitzan, Meir |
author_facet | Elron, Eyal Bromiker, Ruben Gleisner, Ori Yosef-Hai, Ohad Goldberg, Ori Nitzan, Itamar Nitzan, Meir |
author_sort | Elron, Eyal |
collection | PubMed |
description | On average, arterial oxygen saturation measured by pulse oximetry (SpO(2)) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO(2)), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO(2) on 17 cyanotic newborns were performed by means of a Nellcor pulse oximeter (POx), based on light with two wavelengths in the red and infrared regions (660 and 900 nm), and by means of a novel POx, based on two wavelengths in the infrared region (761 and 820 nm). The SpO(2) readings from the two POxs showed higher values than the invasive SaO(2) readings, and the disparity increased with decreasing SaO(2). SpO(2) measured using the two infrared wavelengths showed better correlation with SaO(2) than SpO(2) measured using the red and infrared wavelengths. After appropriate calibration, the standard deviation of the individual SpO(2)−SaO(2) differences for the two-infrared POx was smaller (3.6%) than that for the red and infrared POx (6.5%, p < 0.05). The overestimation of SpO(2) readings in hypoxemia was explained by the increase in hypoxemia of the optical pathlengths-ratio between the two wavelengths. The two-infrared POx can reduce the overestimation of SpO(2) measurement in hypoxemia and the consequent risk of occult hypoxemia, owing to its smaller increase in pathlengths-ratio in hypoxemia. |
format | Online Article Text |
id | pubmed-9921559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99215592023-02-12 Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase Elron, Eyal Bromiker, Ruben Gleisner, Ori Yosef-Hai, Ohad Goldberg, Ori Nitzan, Itamar Nitzan, Meir Sensors (Basel) Article On average, arterial oxygen saturation measured by pulse oximetry (SpO(2)) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO(2)), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO(2) on 17 cyanotic newborns were performed by means of a Nellcor pulse oximeter (POx), based on light with two wavelengths in the red and infrared regions (660 and 900 nm), and by means of a novel POx, based on two wavelengths in the infrared region (761 and 820 nm). The SpO(2) readings from the two POxs showed higher values than the invasive SaO(2) readings, and the disparity increased with decreasing SaO(2). SpO(2) measured using the two infrared wavelengths showed better correlation with SaO(2) than SpO(2) measured using the red and infrared wavelengths. After appropriate calibration, the standard deviation of the individual SpO(2)−SaO(2) differences for the two-infrared POx was smaller (3.6%) than that for the red and infrared POx (6.5%, p < 0.05). The overestimation of SpO(2) readings in hypoxemia was explained by the increase in hypoxemia of the optical pathlengths-ratio between the two wavelengths. The two-infrared POx can reduce the overestimation of SpO(2) measurement in hypoxemia and the consequent risk of occult hypoxemia, owing to its smaller increase in pathlengths-ratio in hypoxemia. MDPI 2023-01-28 /pmc/articles/PMC9921559/ /pubmed/36772474 http://dx.doi.org/10.3390/s23031434 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Elron, Eyal Bromiker, Ruben Gleisner, Ori Yosef-Hai, Ohad Goldberg, Ori Nitzan, Itamar Nitzan, Meir Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase |
title | Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase |
title_full | Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase |
title_fullStr | Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase |
title_full_unstemmed | Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase |
title_short | Overestimation of Oxygen Saturation Measured by Pulse Oximetry in Hypoxemia. Part 1: Effect of Optical Pathlengths-Ratio Increase |
title_sort | overestimation of oxygen saturation measured by pulse oximetry in hypoxemia. part 1: effect of optical pathlengths-ratio increase |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921559/ https://www.ncbi.nlm.nih.gov/pubmed/36772474 http://dx.doi.org/10.3390/s23031434 |
work_keys_str_mv | AT elroneyal overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease AT bromikerruben overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease AT gleisnerori overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease AT yosefhaiohad overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease AT goldbergori overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease AT nitzanitamar overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease AT nitzanmeir overestimationofoxygensaturationmeasuredbypulseoximetryinhypoxemiapart1effectofopticalpathlengthsratioincrease |