Cargando…

Synthesis and Preclinical Evaluation of Three Novel (68)Ga-Labeled Bispecific PSMA/FAP-Targeting Tracers for Prostate Cancer Imaging

Tumor heterogeneity limits the efficacy and reliability of monospecific radiopharmaceuticals in prostate cancer diagnosis and therapy. To overcome this limitation and improve lesion detection sensitivity, we developed and evaluated three bispecific radiotracers that can target both prostate-specific...

Descripción completa

Detalles Bibliográficos
Autores principales: Verena, Arsyangela, Zhang, Zhengxing, Kuo, Hsiou-Ting, Merkens, Helen, Zeisler, Jutta, Wilson, Ryan, Bendre, Shreya, Wong, Antonio A. W. L., Bénard, François, Lin, Kuo-Shyan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9921851/
https://www.ncbi.nlm.nih.gov/pubmed/36770755
http://dx.doi.org/10.3390/molecules28031088
Descripción
Sumario:Tumor heterogeneity limits the efficacy and reliability of monospecific radiopharmaceuticals in prostate cancer diagnosis and therapy. To overcome this limitation and improve lesion detection sensitivity, we developed and evaluated three bispecific radiotracers that can target both prostate-specific membrane antigen (PSMA) and fibroblast activation protein (FAP), which are the two key proteins overexpressed in prostate cancer. Three FAP-targeting ligands with various linker lengths were synthesized through multistep organic synthesis, and then connected to the PSMA-targeting motif. IC(50)(PSMA) and IC(50)(FAP) values of Ga-complexed bispecific ligands, Ga-AV01017, Ga-AV01030, and Ga-AV01038 were 25.2–71.6 and 1.25–2.74 nM, respectively. The uptake values in PSMA-expressing LNCaP tumor xenografts were 4.38 ± 0.55, 5.17 ± 0.51, and 4.25 ± 0.86 %ID/g for [(68)Ga]Ga-AV01017, [(68)Ga]Ga-AV01030, and [(68)Ga]Ga-AV01038, respectively, which were lower than the monospecific PSMA-targeting tracer [(68)Ga]Ga-HTK03041 (23.1 ± 6.11 %ID/g). The uptake values in FAP-expressing HEK293T:hFAP tumor xenografts were 2.99 ± 0.37, 3.69 ± 0.81, 3.64 ± 0.83 %ID/g for [(68)Ga]Ga-AV01017, [(68)Ga]Ga-AV01030, and [(68)Ga]Ga-AV01038, respectively, which were also lower than the monospecific FAP-targeting tracer, [(68)Ga]Ga-FAPI-04 (12.5 ± 2.00 %ID/g). We observed that the bispecific tracers had prolonged blood retention, in which tracers with a longer linker tend to have a higher blood uptake and lower tumor uptake. Further investigations are needed to optimize the linker selection to generate promising bispecific PSMA/FAP-targeting tracers for prostate cancer imaging.