Cargando…

Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?

In Europe, there is a process hygiene criterion for Salmonella and Campylobacter on broiler carcasses after chilling. The criterion gives indicative contamination values above which corrective actions are required by food business operators. The reference methods for verifying compliance with the cr...

Descripción completa

Detalles Bibliográficos
Autores principales: Anis, Nagham, Bonifait, Laetitia, Quesne, Ségolène, Baugé, Louise, Chemaly, Marianne, Guyard-Nicodème, Muriel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967202/
https://www.ncbi.nlm.nih.gov/pubmed/36839610
http://dx.doi.org/10.3390/pathogens12020338
_version_ 1784897205913518080
author Anis, Nagham
Bonifait, Laetitia
Quesne, Ségolène
Baugé, Louise
Chemaly, Marianne
Guyard-Nicodème, Muriel
author_facet Anis, Nagham
Bonifait, Laetitia
Quesne, Ségolène
Baugé, Louise
Chemaly, Marianne
Guyard-Nicodème, Muriel
author_sort Anis, Nagham
collection PubMed
description In Europe, there is a process hygiene criterion for Salmonella and Campylobacter on broiler carcasses after chilling. The criterion gives indicative contamination values above which corrective actions are required by food business operators. The reference methods for verifying compliance with the criterion for Salmonella and Campylobacter are international standards EN ISO 6579-1 (2017) and EN ISO 10272-2 (2017), respectively. These methods are time-consuming and expensive for food business operators. Therefore, it would be advantageous to simultaneously detect Salmonella spp. and quantify Campylobacter in the same analysis, using the same sample after the pre-enrichment step for Salmonella recovery. A duplex PCR for Salmonella detection and Campylobacter spp. enumeration was developed. Considering the method as a whole, the LOD and LOQ for Campylobacter enumeration were slightly over the limit of 3 log CFU/g set by the process hygiene criterion. A comparison of the duplex PCR method developed with the ISO method on artificially contaminated bacterial suspensions and on naturally contaminated samples demonstrated a good correlation of the results for Campylobacter enumeration when the duplex PCR was performed on samples taken before or after the pre-enrichment step, but revealed a slight bias with a large standard deviation resulting in widely spaced limits of agreement.
format Online
Article
Text
id pubmed-9967202
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99672022023-02-26 Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality? Anis, Nagham Bonifait, Laetitia Quesne, Ségolène Baugé, Louise Chemaly, Marianne Guyard-Nicodème, Muriel Pathogens Article In Europe, there is a process hygiene criterion for Salmonella and Campylobacter on broiler carcasses after chilling. The criterion gives indicative contamination values above which corrective actions are required by food business operators. The reference methods for verifying compliance with the criterion for Salmonella and Campylobacter are international standards EN ISO 6579-1 (2017) and EN ISO 10272-2 (2017), respectively. These methods are time-consuming and expensive for food business operators. Therefore, it would be advantageous to simultaneously detect Salmonella spp. and quantify Campylobacter in the same analysis, using the same sample after the pre-enrichment step for Salmonella recovery. A duplex PCR for Salmonella detection and Campylobacter spp. enumeration was developed. Considering the method as a whole, the LOD and LOQ for Campylobacter enumeration were slightly over the limit of 3 log CFU/g set by the process hygiene criterion. A comparison of the duplex PCR method developed with the ISO method on artificially contaminated bacterial suspensions and on naturally contaminated samples demonstrated a good correlation of the results for Campylobacter enumeration when the duplex PCR was performed on samples taken before or after the pre-enrichment step, but revealed a slight bias with a large standard deviation resulting in widely spaced limits of agreement. MDPI 2023-02-16 /pmc/articles/PMC9967202/ /pubmed/36839610 http://dx.doi.org/10.3390/pathogens12020338 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Anis, Nagham
Bonifait, Laetitia
Quesne, Ségolène
Baugé, Louise
Chemaly, Marianne
Guyard-Nicodème, Muriel
Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?
title Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?
title_full Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?
title_fullStr Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?
title_full_unstemmed Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?
title_short Simultaneous Detection of Salmonella spp. and Quantification of Campylobacter spp. in a Real-Time Duplex PCR: Myth or Reality?
title_sort simultaneous detection of salmonella spp. and quantification of campylobacter spp. in a real-time duplex pcr: myth or reality?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9967202/
https://www.ncbi.nlm.nih.gov/pubmed/36839610
http://dx.doi.org/10.3390/pathogens12020338
work_keys_str_mv AT anisnagham simultaneousdetectionofsalmonellasppandquantificationofcampylobactersppinarealtimeduplexpcrmythorreality
AT bonifaitlaetitia simultaneousdetectionofsalmonellasppandquantificationofcampylobactersppinarealtimeduplexpcrmythorreality
AT quesnesegolene simultaneousdetectionofsalmonellasppandquantificationofcampylobactersppinarealtimeduplexpcrmythorreality
AT baugelouise simultaneousdetectionofsalmonellasppandquantificationofcampylobactersppinarealtimeduplexpcrmythorreality
AT chemalymarianne simultaneousdetectionofsalmonellasppandquantificationofcampylobactersppinarealtimeduplexpcrmythorreality
AT guyardnicodememuriel simultaneousdetectionofsalmonellasppandquantificationofcampylobactersppinarealtimeduplexpcrmythorreality