Simulation of dosimetric consequences of intrafraction variation of tumor drift in lung cancer stereotactic body radiotherapy
OBJECTIVE: The purpose of this study was to investigate the target dose discrepancy caused by intrafraction variation during stereotactic body radiotherapy (SBRT) for lung cancer. METHODS: Intensity-modulated radiation therapy (IMRT) plans were designed based on average computed tomography (AVG CT)...