Cargando…

Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer

Metabolic dysfunction of β-cells has been implicated as a contributor to diabetes pathogenesis, and efforts are ongoing to optimize analytical techniques that evaluate islet metabolism. High-resolution respirometry offers sensitive measurements of the respiratory effects of metabolic substrates and...

Descripción completa

Detalles Bibliográficos
Autores principales: Crowder, Justin J., Zeng, Ziqian, Novak, Alissa N., Alves, Nathan J., Linnemann, Amelia K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959522/
https://www.ncbi.nlm.nih.gov/pubmed/35331085
http://dx.doi.org/10.1080/19382014.2022.2054251
_version_ 1784677174365650944
author Crowder, Justin J.
Zeng, Ziqian
Novak, Alissa N.
Alves, Nathan J.
Linnemann, Amelia K.
author_facet Crowder, Justin J.
Zeng, Ziqian
Novak, Alissa N.
Alves, Nathan J.
Linnemann, Amelia K.
author_sort Crowder, Justin J.
collection PubMed
description Metabolic dysfunction of β-cells has been implicated as a contributor to diabetes pathogenesis, and efforts are ongoing to optimize analytical techniques that evaluate islet metabolism. High-resolution respirometry offers sensitive measurements of the respiratory effects of metabolic substrates and customizable manipulation of electron transport chain components, though the delicate nature of islets can pose challenges to conventional analyses. An affordable and reliable option for respirometry is the Oroboros Oxygraph-2 K system, which utilizes a stir bar to circulate reagents around cells. While this technique may be suitable for individual cells or mitochondria, the continual force exerted by the stir bar can have damaging effects on islet integrity. Herein, we demonstrate the protective benefits of a novel 3D-printed islet stabilization device and highlight the destructive effects of conventional Oxygraph analysis on islet integrity. Islet containment did not inhibit cellular responses to metabolic modulatory drugs, as indicated by robust fluctuations in oxygen consumption rates. The average size of wild-type mouse islets was significantly reduced following a standard Mito Stress Test within Oxygraph chambers, with a clear disruption in islet morphology and viability. Alternatively, containment of the islets within the interior chamber of the islet stabilization device yielded preservation of both islet morphology and increased cell viability/survival after respirometry analysis. Collectively, our study introduces a new and easily accessible tool to improve conventional Oxygraph respirometry of pancreatic islets by preserving natural islet structure and function throughout metabolic analysis.
format Online
Article
Text
id pubmed-8959522
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-89595222022-03-29 Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer Crowder, Justin J. Zeng, Ziqian Novak, Alissa N. Alves, Nathan J. Linnemann, Amelia K. Islets Brief Report Metabolic dysfunction of β-cells has been implicated as a contributor to diabetes pathogenesis, and efforts are ongoing to optimize analytical techniques that evaluate islet metabolism. High-resolution respirometry offers sensitive measurements of the respiratory effects of metabolic substrates and customizable manipulation of electron transport chain components, though the delicate nature of islets can pose challenges to conventional analyses. An affordable and reliable option for respirometry is the Oroboros Oxygraph-2 K system, which utilizes a stir bar to circulate reagents around cells. While this technique may be suitable for individual cells or mitochondria, the continual force exerted by the stir bar can have damaging effects on islet integrity. Herein, we demonstrate the protective benefits of a novel 3D-printed islet stabilization device and highlight the destructive effects of conventional Oxygraph analysis on islet integrity. Islet containment did not inhibit cellular responses to metabolic modulatory drugs, as indicated by robust fluctuations in oxygen consumption rates. The average size of wild-type mouse islets was significantly reduced following a standard Mito Stress Test within Oxygraph chambers, with a clear disruption in islet morphology and viability. Alternatively, containment of the islets within the interior chamber of the islet stabilization device yielded preservation of both islet morphology and increased cell viability/survival after respirometry analysis. Collectively, our study introduces a new and easily accessible tool to improve conventional Oxygraph respirometry of pancreatic islets by preserving natural islet structure and function throughout metabolic analysis. Taylor & Francis 2022-03-25 /pmc/articles/PMC8959522/ /pubmed/35331085 http://dx.doi.org/10.1080/19382014.2022.2054251 Text en © 2022 The Author(s). Published with license by Taylor & Francis Group, LLC. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Brief Report
Crowder, Justin J.
Zeng, Ziqian
Novak, Alissa N.
Alves, Nathan J.
Linnemann, Amelia K.
Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer
title Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer
title_full Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer
title_fullStr Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer
title_full_unstemmed Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer
title_short Stabilization protects islet integrity during respirometry in the Oroboros Oxygraph-2K analyzer
title_sort stabilization protects islet integrity during respirometry in the oroboros oxygraph-2k analyzer
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959522/
https://www.ncbi.nlm.nih.gov/pubmed/35331085
http://dx.doi.org/10.1080/19382014.2022.2054251
work_keys_str_mv AT crowderjustinj stabilizationprotectsisletintegrityduringrespirometryintheoroborosoxygraph2kanalyzer
AT zengziqian stabilizationprotectsisletintegrityduringrespirometryintheoroborosoxygraph2kanalyzer
AT novakalissan stabilizationprotectsisletintegrityduringrespirometryintheoroborosoxygraph2kanalyzer
AT alvesnathanj stabilizationprotectsisletintegrityduringrespirometryintheoroborosoxygraph2kanalyzer
AT linnemannameliak stabilizationprotectsisletintegrityduringrespirometryintheoroborosoxygraph2kanalyzer