Cargando…
High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
BACKGROUND: The risks of metal release due to fretting and corrosion at the head–neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of mo...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830807/ https://www.ncbi.nlm.nih.gov/pubmed/36627685 http://dx.doi.org/10.1186/s13018-023-03510-4 |
_version_ | 1784867741570695168 |
---|---|
author | Kobayashi, Kyosuke Kidera, Kenichi Shiraishi, Kazuteru Okazaki, Narihiro Chiba, Ko Yonekura, Akihiko Osaki, Makoto |
author_facet | Kobayashi, Kyosuke Kidera, Kenichi Shiraishi, Kazuteru Okazaki, Narihiro Chiba, Ko Yonekura, Akihiko Osaki, Makoto |
author_sort | Kobayashi, Kyosuke |
collection | PubMed |
description | BACKGROUND: The risks of metal release due to fretting and corrosion at the head–neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of motion, it has remained unclear whether this change affects metal release and ALTR in vivo. This study aimed to investigate serum metal concentrations and the prevalence of ALTR in MoP THA with a 9/10-mm stem trunnion. PATIENTS AND METHODS: A consecutive series of 37 hips that underwent THA using MoP grafted with poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) with a 9/10-mm trunnion stem were retrospectively reviewed. Serum metal levels were assessed and compared with those in MoP THA with a 10/12-mm trunnion stem. ALTR was diagnosed with serum metal levels and cross-sectional images. The factors associated with serum metal levels were also assessed. RESULTS: The median serum cobalt and chromium levels were 1.5 μg/L and 1.0 μg/L in the 9/10-mm group and 0.2 μg/L and 0.4 μg/L in the 10/12-mm group, respectively. ALTR was found in 5 hips of 3 patients. Revision surgery was performed in 4 hips, and all stem trunnions and femoral heads showed severe corrosion. Postoperative walking ability was associated with serum metal levels. CONCLUSION: It was found that a 9/10-mm stem trunnion with MoP grafted with PMPC had high risks of metal release in primary THA. Careful follow-up and cross-sectional imaging are needed to detect ALTR for early revision. |
format | Online Article Text |
id | pubmed-9830807 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98308072023-01-11 High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty Kobayashi, Kyosuke Kidera, Kenichi Shiraishi, Kazuteru Okazaki, Narihiro Chiba, Ko Yonekura, Akihiko Osaki, Makoto J Orthop Surg Res Research Article BACKGROUND: The risks of metal release due to fretting and corrosion at the head–neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of motion, it has remained unclear whether this change affects metal release and ALTR in vivo. This study aimed to investigate serum metal concentrations and the prevalence of ALTR in MoP THA with a 9/10-mm stem trunnion. PATIENTS AND METHODS: A consecutive series of 37 hips that underwent THA using MoP grafted with poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) with a 9/10-mm trunnion stem were retrospectively reviewed. Serum metal levels were assessed and compared with those in MoP THA with a 10/12-mm trunnion stem. ALTR was diagnosed with serum metal levels and cross-sectional images. The factors associated with serum metal levels were also assessed. RESULTS: The median serum cobalt and chromium levels were 1.5 μg/L and 1.0 μg/L in the 9/10-mm group and 0.2 μg/L and 0.4 μg/L in the 10/12-mm group, respectively. ALTR was found in 5 hips of 3 patients. Revision surgery was performed in 4 hips, and all stem trunnions and femoral heads showed severe corrosion. Postoperative walking ability was associated with serum metal levels. CONCLUSION: It was found that a 9/10-mm stem trunnion with MoP grafted with PMPC had high risks of metal release in primary THA. Careful follow-up and cross-sectional imaging are needed to detect ALTR for early revision. BioMed Central 2023-01-10 /pmc/articles/PMC9830807/ /pubmed/36627685 http://dx.doi.org/10.1186/s13018-023-03510-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Kobayashi, Kyosuke Kidera, Kenichi Shiraishi, Kazuteru Okazaki, Narihiro Chiba, Ko Yonekura, Akihiko Osaki, Makoto High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
title | High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
title_full | High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
title_fullStr | High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
title_full_unstemmed | High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
title_short | High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
title_sort | high risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830807/ https://www.ncbi.nlm.nih.gov/pubmed/36627685 http://dx.doi.org/10.1186/s13018-023-03510-4 |
work_keys_str_mv | AT kobayashikyosuke highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty AT kiderakenichi highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty AT shiraishikazuteru highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty AT okazakinarihiro highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty AT chibako highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty AT yonekuraakihiko highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty AT osakimakoto highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty |