Cargando…

High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty

BACKGROUND: The risks of metal release due to fretting and corrosion at the head–neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of mo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kobayashi, Kyosuke, Kidera, Kenichi, Shiraishi, Kazuteru, Okazaki, Narihiro, Chiba, Ko, Yonekura, Akihiko, Osaki, Makoto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830807/
https://www.ncbi.nlm.nih.gov/pubmed/36627685
http://dx.doi.org/10.1186/s13018-023-03510-4
_version_ 1784867741570695168
author Kobayashi, Kyosuke
Kidera, Kenichi
Shiraishi, Kazuteru
Okazaki, Narihiro
Chiba, Ko
Yonekura, Akihiko
Osaki, Makoto
author_facet Kobayashi, Kyosuke
Kidera, Kenichi
Shiraishi, Kazuteru
Okazaki, Narihiro
Chiba, Ko
Yonekura, Akihiko
Osaki, Makoto
author_sort Kobayashi, Kyosuke
collection PubMed
description BACKGROUND: The risks of metal release due to fretting and corrosion at the head–neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of motion, it has remained unclear whether this change affects metal release and ALTR in vivo. This study aimed to investigate serum metal concentrations and the prevalence of ALTR in MoP THA with a 9/10-mm stem trunnion. PATIENTS AND METHODS: A consecutive series of 37 hips that underwent THA using MoP grafted with poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) with a 9/10-mm trunnion stem were retrospectively reviewed. Serum metal levels were assessed and compared with those in MoP THA with a 10/12-mm trunnion stem. ALTR was diagnosed with serum metal levels and cross-sectional images. The factors associated with serum metal levels were also assessed. RESULTS: The median serum cobalt and chromium levels were 1.5 μg/L and 1.0 μg/L in the 9/10-mm group and 0.2 μg/L and 0.4 μg/L in the 10/12-mm group, respectively. ALTR was found in 5 hips of 3 patients. Revision surgery was performed in 4 hips, and all stem trunnions and femoral heads showed severe corrosion. Postoperative walking ability was associated with serum metal levels. CONCLUSION: It was found that a 9/10-mm stem trunnion with MoP grafted with PMPC had high risks of metal release in primary THA. Careful follow-up and cross-sectional imaging are needed to detect ALTR for early revision.
format Online
Article
Text
id pubmed-9830807
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98308072023-01-11 High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty Kobayashi, Kyosuke Kidera, Kenichi Shiraishi, Kazuteru Okazaki, Narihiro Chiba, Ko Yonekura, Akihiko Osaki, Makoto J Orthop Surg Res Research Article BACKGROUND: The risks of metal release due to fretting and corrosion at the head–neck junction and consequent adverse local tissue reaction (ALTR) have concerns in metal-on-polyethylene (MoP) total hip arthroplasty (THA). Although trunnions have become thinner in diameter to increase the range of motion, it has remained unclear whether this change affects metal release and ALTR in vivo. This study aimed to investigate serum metal concentrations and the prevalence of ALTR in MoP THA with a 9/10-mm stem trunnion. PATIENTS AND METHODS: A consecutive series of 37 hips that underwent THA using MoP grafted with poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) with a 9/10-mm trunnion stem were retrospectively reviewed. Serum metal levels were assessed and compared with those in MoP THA with a 10/12-mm trunnion stem. ALTR was diagnosed with serum metal levels and cross-sectional images. The factors associated with serum metal levels were also assessed. RESULTS: The median serum cobalt and chromium levels were 1.5 μg/L and 1.0 μg/L in the 9/10-mm group and 0.2 μg/L and 0.4 μg/L in the 10/12-mm group, respectively. ALTR was found in 5 hips of 3 patients. Revision surgery was performed in 4 hips, and all stem trunnions and femoral heads showed severe corrosion. Postoperative walking ability was associated with serum metal levels. CONCLUSION: It was found that a 9/10-mm stem trunnion with MoP grafted with PMPC had high risks of metal release in primary THA. Careful follow-up and cross-sectional imaging are needed to detect ALTR for early revision. BioMed Central 2023-01-10 /pmc/articles/PMC9830807/ /pubmed/36627685 http://dx.doi.org/10.1186/s13018-023-03510-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Kobayashi, Kyosuke
Kidera, Kenichi
Shiraishi, Kazuteru
Okazaki, Narihiro
Chiba, Ko
Yonekura, Akihiko
Osaki, Makoto
High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
title High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
title_full High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
title_fullStr High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
title_full_unstemmed High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
title_short High risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
title_sort high risk of elevated metal concentrations with 9/10-mm stem trunnions and highly cross-linked polyethylene grafted with poly(2-methacryloyloxyethyl phosphorylcholine) in total hip arthroplasty
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9830807/
https://www.ncbi.nlm.nih.gov/pubmed/36627685
http://dx.doi.org/10.1186/s13018-023-03510-4
work_keys_str_mv AT kobayashikyosuke highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty
AT kiderakenichi highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty
AT shiraishikazuteru highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty
AT okazakinarihiro highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty
AT chibako highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty
AT yonekuraakihiko highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty
AT osakimakoto highriskofelevatedmetalconcentrationswith910mmstemtrunnionsandhighlycrosslinkedpolyethylenegraftedwithpoly2methacryloyloxyethylphosphorylcholineintotalhiparthroplasty